Below is a comparison chart that includes all of our compressor models.

We have also divided the charts into the following categories for easier reading:

Portable Compressor Comparison Chart

5000 PSI Compressor Comparison Chart

6000 PSI Compressor Comparison Chart

 

 

Model Number CFM Driver Phase HP PSI Stages Filter Capacity @ 68 degrees Filter # Estimated Hours before filter change at 68 degrees Magnetic Starter Manual Drain System Auto Drain CO- Moisture Indicator Gauge Panel High Pressure Switch Electrical 208/230 V60 Hertz RPM Cabinet Style Dimensions w" x d" h" Weight Printable Flyer (Needs Acrobat Reader)
NA-G 3.5 Gas Single 6 4700 4 3,000 cf X-N-ATL 17 hours No Standard No No No No N/A 2300 Open w/ guards 29 X 16.5 X 16 90 lbs NA Compressor
NA-E1 3.5 Electric Single 3 4700 4 3,000 cf X-N-ATL 17 hours No Standard No No No No 30 amp 2300 Open w/ guards 23 X 16.5 X 16 87 lbs NA Compressor
CS1 - G 3.5 Gas Single 5 4800 4 3,000 cf X152412 17 hours No Standard No No No No N/A 2800 Open w/ guards 14.2 X 12.6 X 29.5 87 lbs CS1 Compressor
CS1-SS-E1 3.5 Electric Single 5 4800 4 3,000 cf X152412 17 hours No Standard No No No No 30 amp 2800 Enclosed 14.2 X 14 X 25.5 95 lbs CS1 Compressor
CS1-SS-G 3.5 Gas Single 3 4800 4 3,000 cf X152412 17 hours No Standard No No No No N/A 2800 Enclosed 14.2 X 14 X 25.5 95 lbs CS1 Compressor
CS1-E1 3.5 Electric Single 3 4800 4 3,000 cf X152412 17 hours No Standard No No No No 30 amp 2800 Open w/ guards 14.2 X 15 X 25.5 87 lbs CS1 Compressor
NP-G 6.5 Gas Single 9 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 43 hours -Option 100 hours No Standard No No No No N/A 1550 Open w/ guards 42 x 24 x 26 350 lbs NP-G Compressor
NP-5E1 6.5 Electric Single 5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 43 hours -Option 100 hours Standard Standard Optional Optional No Optional 30 amp 1350 Open w/ guards 42 x 21 x 24 320 lbs NP-5E1 Compressor
NP-5E3 6.5 Electric Three 5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 43 hours -Option 100 hours Standard Standard Optional Optional No Optional 30 amp 1350 Open w/ guards 42 x 21 x 24 320 lbs NP-5E3 Compressor
NP-7.5E1 9 Electric Single 7.5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 31 hours -Option 74 hours Standard Standard Optional Optional No Optional 40 amp 1550 Open w/ guards 42 x 21 x 24 330 lbs NP-7.5E1 Compressor
NP-7.5E3 9 Electric Three 7.5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 31 hours -Option 74 hours Standard Standard Optional Optional No Optional 30 amp 1550 Open w/ guards 42 x 21 x 24 330 lbs NP-7.5E3 Compressor
NS-5E1 6.5 Electric Single 5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 43 hours -Option 100 hours Standard No Standard Standard Standard Standard 30 amp 1350 Enclosed 39 x 29 x44 550 lbs NS-5E1 Compressor
NS-5E3 6.5 Electric Three 5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 43 hours -Option 100 hours Standard No Standard Standard Standard Standard 30 amp 1350 Enclosed 39 x 29 x44 550 lbs NS-5E3 Compressor
NS-7.5E1 9 Electric Single 7.5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 31 hours -Option 74 hours Standard No Standard Standard Standard Standard 40 amp 1550 Enclosed 39 x 29 x44 550 lbs NS-7.5E1 Compressor
NS-7.5E3 9 Electric Three 7.5 5000 3 11,550 cf optional 54,000 cf X302414Option X65247 31 hours -Option 74 hours Standard No Standard Standard Standard Standard 30 amp 1550 Enclosed 39 x 29 x44 550 lbs NS-7.5E3 Compressor
NC-7.5E1 9 Electric Single 7.5 6000 4 17,000 cf optional 40,000 cf X65240 31 hours -Option 74 hours Standard No Standard Standard Standard Standard 40 amp 1100 Enclosed 39 x 29 x44 550 lbs NC-7.5E1 Compressor
NC-7.5E3 9 Electric Three 7.5 6000 4 17,000 cf optional 40,000 cf X65240 31 hours -Option 74 hours Standard No Standard Standard Standard Standard 30 amp 1100 Enclosed 39 x 29 x44 550 lbs NC-7.5E3 Compressor
NC-10E1 14 Electric Single 10 6000 4 40,000 cf optional 100,000 cf X65247 50 hours - Option 120 hours Standard No Standard Standard Standard Standard 50amp 1550 Enclosed 39 x 29 x44 600 lbs NC-10E1 Compressor
NC-10E3 14 Electric Three 10 6000 4 40,000 cf optional 100,000 cf X65247 50 hours - Option 120 hours Standard No Standard Standard Standard Standard 40amp 1550 Enclosed 39 x 29 x44 600 lbs NC-10E3 Compressor
NC-15E3 21 Electric Three 15 6000 4 100,000 cf X65247/X65677 100 hours Standard No Standard Standard Standard Standard 50 amp 1100 Enclosed 46 x 29 x 45 900 lbs NC-15E3 Compressor
NC-20E3 24 Electric Three 20 6000 4 100,000 cf X65247/X65677 75 hours Standard No Standard Standard Standard Standard 60 amp 1300 Enclosed 46 x 29 x 45 900 lbs NC-20E3 Compressor
NC-20E3Industrial 24 Electric Three 20 6000 4 100,000 cf X65247/X65677 75 hours Standard No Standard Standard Standard Standard 60 amp 1300 Open w/ guards 57 x 34 x 35 850 lbs NC-20E3 Ind. Compressor

 

Temperature Correction Table: In order to know the estimated number of hours that a filter will last, you need to
multiply the number of hours at 68° F by the conversion factor.

Celsius

Fahrenheit Conversion Factor Example: hours (ex. 21 hours) x factor = estimated hours
50 122 0.2 21 x 0.2 = 4.2 hours
40 104 0.34 21 x 0.34 = 7.1 hours
30 86 0.57 21 x 0.57 = 12.0 hours
20 68 1 21 hours
10 50 1.85 21 x 1.85 = 38.9 hours
5 41 2.6 21 x 2.6 = 54.6 hours
0 32 3.8 21 x 3.8 = 79.8 hours